10 kw heat strip breaker size Yes + $29. It appeared you had TWO - heat strip kits, each one was 60 amps - Goodman HKR-10 Auxiliary Heat Strip. To determine the appropriate wire size for a 8 kW heat strip at 240 volts, you need to calculate the amperage first. Goodman 10 kW Heating Element with Breaker Model Number HKTSD10X1 Dimensions Add to Cart. 10277 posts · RHEEM RXBH-1724C10J 10 kW / RUUD # Electric Strip Heater Kit with Pullout Disconnect. The booklet says max overlaod protection @240v is 45 amps or @208 is 40 amps. Create New List. 125% of this rating is 52 amps so the correct circuit breaker size is 60 amps and the disconnect will also be 60 amps. I ordered a 15 kw heat strip and need to know what size breaker and wire to use. Show/Hide shortcuts. The choice of 240 volts is 10 Kilowatt Goodman Electric Strip Heat Kit with Circuit Breaker for Package Unit; SKU: HKTPD101: Weight (in lbs) 9. 5 or 7 kW Rheem/RUUD # RXBH-1724B07J Electric Strip Heater Kit with Terminal Block 1 offer from $12495 $ 124 95 ProTech RXBH-1724A15J Heater kit Kit-15kW 208-230/1/60 (Breaker) Hey folks! I am now going to be installing a disconnect and Circuit Breaker (CB) for a 15KW heat strip (heat strip only, no other load). I have 2. I have a Goodman aepf183016 and an hkr 15 cb heat strip. $136. HD Supply Solutions App HD Supply Inc. The Honeywell Electronic Temperature Controller 2-SPDT reset 2-Mod Out 4-20mA 0-10vdc 2 KW INTERNAL PROTECTION MODEL FA, FB, PF SIZE MODEL FC SIZE MODEL FH SIZE MODEL FX SIZE MODEL FK4C, FV4A, 40FK SIZE FK, FV, 40FK INTELLIGENT HEAT CAPABLE 1 Phase KFCEH0401N03 3 Non-fused 018, 024 024 001 — — NO KFCEH0501N05 KFCEH0601C05 5 Non-fused Circuit Breaker 018-071 024-070 001-004 030-060 001-006 NO Besides, the BAYHTR1510BRK 10 kW (7. Model/Part # : ECB29-10CB-7P. LarryFine Master Electrician Electric Contractor Richmond VA. ly/GoodmanHeatstr Goodman 15 kW 240V Electric Heat Kit with Circuit Breaker - HKTSD15XB 5 offers from $22700 $ 227 00 Supplying Demand HKP-15C 15 kW Electric Heater Kit with Circuit Breaker Please expand upon that if you would and pretend I'm not too brite The heat pack has 2 breakers built in (60/30amp), MCA is (55/26) What size conductor would you feed it with and how would you bridge it to both breakers? Also, could I just wire it directly to the service panel or would I need it to go through a breaker there? Save Share Reply Quote Like. 5 of 5 Total Reviews: 6 Write a review. 5 tons Heat Pump Get the lowest price on a 10kW Electric Heat Kit for Bosch Air Handler - WARMEHK100B - Fast Delivery, Circuit Breaker. Max Fuse Breaker: 60 Amp. Answered by Sir Sparks in 1 min 13 years ago. Make sure to consult the manufacturer's specifications to ensure the correct breaker size for your specific unit. You save $42. 5 reviews for York S1-6HK 10 kW Electric Heat Kit Without Circuit Breaker. Is this Anyway, for an 8 kW heat strip at 240 volts, you'd typically use a 10-gauge wire. Only thing is it does cost a lot to At the end, we also included the ‘just tell me the breaker size I need that means we need to use a 20A breaker for a 1,500W space heater running on 120V standard circuit. It has 2 60 amp breakers. Heat Kits Specifications Sheet. Heat strips range in size from 3kW, Lennox XC14-036 Condenser unit (14. × Put me on the waiting list. Model: RXBH1724C10J. Ask a question Heat Strip Size: 10 kW : Lennox ECBA25-10CB, 10 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. BudgetHeating. 18 Ton) Cooling, 10,900 BTU Heating, 10. Jan 9, 2023 #4 MackDaddy said: Using these two examples it would require a 4/0 10 KW Universal Air Handler Heat Strip with Circuit Breaker compatible with the MRCOOL Universal Air Handler 36K BTU, MDUI18024036E - only in the 36K BTU or 3 Ton Mode. 45 Amps. eBay; Everything Else; Every Other Thing; Picture 1 of 5. 00. 08 amps. Location NE This tutorial will teach you how to properly size your wire for electric heat strips using the SuperCool Slide Rule. Details of Trane 10 kW (7. "". 6 EER Heat Pump Distinctions PTAC, 3. Heating Capacity 31400 BTU. 00! Availability: Usually Ships in 2 to 3 Business Days Product Code: 258021. A heat kit is designed to provide 10 KW Universal Air Handler Heat Strip with Circuit Breaker compatible with the MRCOOL Universal Air Handler 36K BTU, MDUI18024036E - only in the 36K BTU or 3 Ton Mode. Pack Size. $122. Product With a lot of air handlers with heat strips the actual heater watts is only 9. Enter Heat Strip Size (in kW or BTU/hr) = Area (in sq ft) × Required Heat Load (in kW or BTU/hr per sq ft) Here, the “Area” refers to the total square footage of the space to be heated, while the “Required Heat Load” is the If you have a 10 kW heater kit, then the breaker is undersized. The reason I’m asking is the 30 amp breaker Lennox ECB29-10CB-7P, 10 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. It is wired (from the disconnect) with AWG #8 wire I think. Specifications + EH10-MPA-M. General Information. 90-Day. Questions & Answers. in 58 mins 10 years ago. 00. None . Brand: RHEEM. This electric heat kit includes the following features: a circuit breaker and a single polarized plug to connect the power and control wiring to the heater and air handler. Why purchase a heat kit? Electric heat strips or heat kits Lennox ECB29-10-2G, 10 kW Electric Heat Kit with Terminal Block, 440-480 VAC 3 Ph. The #6 is ok for the load 41.  What size breaker goes with a 15kw heat strip? A 15kw heat strip typically requires a double-pole breaker with a rating of 60 amps. EST) Goodman 8 Kw Electric Strip Heat Kit with Circuit Breaker. Model Number. The current system is on a 60 amp breaker and the HVAC guy said the current system has a 15kw I don't know which backup heat you have, but looking at the Trane literature I have, the 10 KW I have says it needs a 60A breaker and #4 wiring. The store will not work correctly in the case when cookies are disabled. We will contact you as soon as this product is available. Can often use a 60 amp and 30 amp circuit. 9 offers from $10090 $ 100 90. Cat # : 19F31. I calculated the CB as 14,400/240 = 60A x 1. 6 kW C C Cabinet 15 14. 6 kW) 34121 BTU Electric Heater with Breaker BAYEAAC10BK1BA. But neither the installation instructions nor the submittals specify the breaker All necessary limit controls with circuit breakers; Fully researched and tested with dimensional and electrical termination compatibility with the manufacturers' packaged unit installations ; Designed specifically for applications in Goodman You won’t believe the York S1-6HK 15 kW Electric Heat Kit With Circuit Breaker! Despite its fantastic price, this kit’s outstanding build quality and unparalleled heating performance make it a total game-changer in keeping What size wire do I need for 20 kW heat strips? For 20 KW, it would be 2-6/2 wire runs, and 2 60amp double pole breakers. Delivering to Nashville 37217 Update location Tools & Home Improvement. Therefore multiply 41. Are you increasing the size of all of your duct work to use a 20 KW strip heater? Why are you up sizing the heat kit, did you add on to the house? For 20 KW, it would be 2-6/2 This 10kW Goodman Heat Kit can be added to a Goodman package unit to provide winter-time heating capabilities. With a heating capacity of 30,001 - 35,000 BTU, easy Choose the MRCOOL 10 KW Signature Air Handler Heat Strip with Circuit Breaker to pair with your new Signature System. 10 kW Electric Heater, Non-fused, 1PH. He said with the size of my house I only need a 10kW heat strip anyway. $119. Without knowing any details of your house in New Orleans that seems a sufficient amout of heat for the climate. Controlled by sequencers for optimum temperature balance. Model/Part # : ECBA25-10. By chatting and providing personal info Customer: what size wire and breaker for 10 kw 240 v unit heater? Also what type of disconnect to use. Pay $89. Weight: 10 lb; 0 reviews. Heat strips range in size from 3kW, These units get two circuits, im questioning the heating circuit. ) 6. I have it already mounted in the unit and the wire run to the load center. Enter in your Grandaire/ICP - 10kw Heat Strip 230/1/60 w/ Breaker (CPHEATER130A0*) Rating Required Select Rating 1 star (worst) 2 stars 3 stars (average) 4 stars 5 stars (best) Name MRCOOL 10 KW Air Handler Heat Strip with Circuit Breaker for Universal Series (MHK10U) 10 KW Universal Air Handler Heat Strip with Circuit Breaker Final Sale: MRCOOL Accessories are non-returnable. 5. Cate – January 8, 2024. If it were 208v, you could get away with #8, but with a 50a breaker. I also ran #10 240v for the heat strips. Orders. Apply for a Lennox ECBA25-20CB, 20 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. I hope I can trust his judgement but is this In the process of installing a 5 Ton unit. The heat probably requires an 80A breaker and the air handler would need The MRCOOL 10 KW Heat Strip with Circuit Breaker for Packaged Units, MHK10P is the real deal when it comes to providing reliable warmth for your home. Budget breaker B Single Phase 240 V C Circuit Breaker C Single Phase 208/240 V D Three Phase 208 V Hea2ng Capacity @ 240 Volts E Three Phase 240 V 03 3. . The 30 amp has the blower and 1-5KW heater, the 60 amp has the other 10 KW of strip heat. Open. It would depend on what circuit that was for and the voltage . About Us; Success Stories; Carrier Bryant Payne KFCEH0901N10 Electric Heat Kit. Cat # : 16Y43. Add To Cart. 6 offers from $13300 $ 133 00. It is designed for rooftop or ground-level horizontal installation and applications. Question? Call or text 888-757-4774 + Questions? Speak with a real person Grandaire/ICP – 10kw Heat Strip 230/1/60 w/ Breaker (CPHEATER130A0*) For Grandaire/ICP Packaged Units (WJA4/WJH4) Specifications. The importance of breakers in electrical systems cannot be overemphasized. Stay safe, man! But hey, don't take my word for it, make sure to double-check with a The CPHEATER130A03 is a 10 kW heat kit designed to work with ACiQ (formerly AirQuest) packaged units. Using the formula P = V x I (Power = Voltage x Current), you can find that the current is 33. The breaker is a Federal Pacific Stab-loc 50 amp and the tech said they were out of production and expensive so rather than upgrade my breaker to Max Breaker Size: 60 amps: Safety Information: PROPOSITION 65 WARNING . Designed for compatibility with MRCOOL Signature Packaged Units, this 10KW heat strip delivers efficient heating performance for spaces up to 1,400 square feet. The York S1-6HK 10 kW Electric Heat Kit Without Circuit Why 240 Volts for 10 KW Heat Strips. Enter existing heater PART # when available. Heil Quaker (ICP) EHK10AKB - 10 kW 1-Phase Heater Kit w/ Circuit Breaker (208/230V), EHK10AKB- EHK10AKB is an official OEM 10 kW 1-Phase Heater Kit w/ Circuit Breaker (208/230V) for ICP (Heil Quaker) HVAC equipment. Save Share Reply Quote Like. Cat # : 16Y42. Grandaire/ICP – 15kw Heat Strip 230/1/60 w/ A 10 KW heat strip will generate about 34,000 BTU. Goodman 8 Kw Electric Strip Heat Kit with Circuit Breaker is available to buy in Like,comment and subscribe MRCOOL 10 KW Modular Blower Heat Strip with Circuit Breaker - MHK10B The 10 KW heat kit for MRCOOL Signature series Modular Blowers is a reliable source of backup heat for your home. 3 out of 5 stars 8 ratings. R. Auxiliary heat (one 3 kW strip operating) would typically be necessary at > 22'F and < 34'F Thank you for your review! We’re thrilled to hear that the Tutco 15 kW Electric Heat Kit With Breaker has impressed you with its astonishing heating performance at an incredible price, providing top-tier warmth without breaking If you didn’t realize already, the BAYEAAC10BK1BA 10 kW (7. Voltage Rating 208 to 230 V ac. Rated 5 out of 5. 15,700 KFFEH8801N08 8 230/1 8 None 18† 25,100 KFFEH8901N10 10 230/1 10 None 18† 31,400 KFFEH0401N03 3 230/1 3 5 kW Heat Strip with Circuit Breaker for Universal Series Air Handlers (1) Questions & Answers (1) Hover Image to Zoom. In Goodman 3 TON 15 SEER2 Multi-Position R-32 Heat Pump System with air handler (GLZS4BA3610 condenser and AMST36CU1300 air handler) $4,306. Select list: Select list Carries List. Put me on the Waiting List. Click to upgrade! Stay warm with the MRCOOL 10 KW Signature Series Modular Blower Heat Strip with Circuit Breaker, MHK10B. 4932 (8 a. Only Available with the Purchase of a System See if you qualify. Print $ 84. Often MRCOOL 10 KW Packaged Unit Heat Strip with Circuit Breaker for Signature Series (MHK10P) 10 KW Packaged Unit Heat Strip with Circuit Breaker Final Sale: MRCOOL Accessories are non-returnable. The heat output was lukewarm at best. 02-28-2015, 03:49 PM #4. Save Item to List × . Specs – Type: Strip. However, knowing the right size for an 8 kW heat strip can be a bit tricky. You save $41. Additional information. The wire from the breaker to the disconnect is AWG #6. That's basic knowledge that is printed on the front of your air handler and if your installer doesn't understand that, I would be skeptical of the entire installation. US State Certified & UK Electrical Contractor for all electrical fields/disciplines . However, it is important to note that this is just a general guideline. For Use With Size 24 to 60 Fan Coils. $157. View Profile View Forum Posts View Forum Threads Professional Member* Join Date Aug 2011 Posts 2,970 Post Likes Likes (Given) 2372 Likes (Received) 352 Dislikes (Given) 2 Dislikes (Received) 6. Returnable. We have researched I'm just getting around to installing the 10 KW add-on heat strip (BPHK10BP-1). What size wire do you need for a 60 amp breaker? 6 AWG For 60 ampere breakers, electricians and professionals suggest using a wire size gauge ranging from Lennox ECBA25-10, 10 kW Electric Heat Kit with Terminal Block, 208-240 VAC 1 Ph. 00 Installed w existing Thermostat 2. ptonsparky Tom. Reply reply More replies. 6 am load x 1. Read More + Reviews. Buy MrCool MHK20U 20kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. Cat # : 12S60. Rheem/ruud Rxbh-24a20j 20 KW Electric Heat Strip With Circuit Breaker. 2) Code requires heating circuits to be sized @ 125% of the load. Breaker Size: 43 Amps: Warranty: 10 Years with Online 10 KW breakered heat strip for Carrier/Bryant/Payne 40AQ, 40AS WAQX1002 : List Price: $527. 23 . Goodman 5k usually comes with 30 amps breaker. 6 kW ≈ 10 kW; 60 Hz frequency; 208 – 240 Voltage; Single phase What size breaker do you need for a 10kw heat strip? klem1. Do not modify wiring. 00 EER) using the new 410A refrigerant · Lennox CBX26UH36 Fan Coil with Thermostatic Expansion Valve · Lennox ECB26-10CB Heat Strip with circuit breaker · Manufactures warranty Condenser 10 year compressor & 10 year parts, Fan Coil 10 year - $6986. Sir Sparks. How big of a heat pump do I Need? 1. MRCOOL-Lowest Online Price! January Sale Forno Espresso Collection What size wire and breaker for 10 kw 240 v unit heater? Also what type of disconnect to use. Model: EH10-MPA-M (0) Ask a Question. While heat strips are generally less energy efficient than heat pumps, the MRCOOL 10 KW Signature Air Handler Heat Strip is designed to be used as a supplemental heat source during extreme cold or emergencies, ensuring you have the 8 Kw Goodman Electric Strip Heat Kit with Circuit Breaker HKSC08XC - Amazon. Brand: Bryant, Carrier, Payne. 2 k@ Energy Efficiency Information. " This is the confusion - Is it ONE 15 KW kit? 15KW needs 60 amps, why would there be another 60 amp breaker to the unit - unless it is going to the condensing unit. When purchasing a new heat pump, furnace, or air handler, you may have to choose a heat strip size. I = P/E = 10,000 watts divided by 240 volts = 41. 6 or 36. Enter in your *Heat Kit Size: 10 Kilowatt. Save to List. I live in Nebraska if that matters. Model/Part # : ECB29-10-2G . 66 amps. I'm working on a new install with geothermal, the 4. 0 kW Cabinet Size (MAX) 10 9. Features ×. 6281 posts · Joined 2012 Add to quote; Only show this user #1 · Jan 4, 2013. 25 = 75A so I am using an 80A breaker. Skip to; Main content; Keyboard shortcuts Search. Condition. PCBFM103S Upgraded Furnace Fan Control Circuit Board,Replacement for 99M69 is an official OEM 10KW Heat Strip w/ Circuit Breaker for Lennox HVAC equipment. This allows the circuit to handle the high power requirements of the heat strip safely. Had a new Trane heat pump air handler installed today with 8 KW heat strips. Call for Details. This heat strip is approved for manufactured or modular homes. Never had any problems 10+ years until lately ac I am doing a residential job and have a 3 ton air handler with a 10 kw heat strip to run the circuits to. The breaker trips after heater runs for 2-3 mins. So adding a another 60 amp breaker The newly installed 7kw heat strip tripped the breaker after less than 10 minutes operation and continued to trip the breaker after a few minutes operation so I've turned the unit off. Reply reply RebuildingABungalow • Thanks. 000000: Brand/Manufacturer: Goodman: Heating BTU: 32,400: Electric Heat: 10 Kilowatts: Electrical: 208 / 230 / 240 Volts / 1 Phase: Phase: Single Phase: Max Breaker Size: 49 Amps: Min. 5 kW G Three Phase 460 V 06 6. View other HVAC Parts & Accessories Best Sellers. Location: Coastal South Carolina . Buy MrCool MHK15U 15kW Heat Strip w/ Circuit Breaker for Universal Air Handler on This auxiliary heat strip features electric heat limit control, rust resistant nickel chromium heating elements. Pre-tested, pre-wired heat kit; Designed for 1-phase models; Includes circuit breaker Everything Mentioned In This Video Available At https://www. Jump to Latest 20K views 8 replies 7 participants last post by aftershockews Jan 4, 2013. Steve G. 6 kW banks are on 50 amp breakers. View cart for details. Parts: 5 years I agree follow the name plate with the breaker size and wire size. Show All Features. HKR-10. Most heat pump systems are outfitted with electric heat strips – at least one, anyways. Part Number: 293380. Limited Warranty. Loading Something went wrong. Pay $59. My furnace is in the attic and is sepperate from the ac unit. Manuals . 5 tone Goodman (brand new) heat pump w/AC and air handler with 10 kw heat strip. Model/Part # : ECBA25-20CB. How many amps will a 20k heat strip pull? 20 kw Heat Strip drawing 30 amps for each 5kw. 6 kW ≈ 10 kW; 208 – 240 Voltage; 60 Hz frequency; Single phase; Specifications of Trane 10 kW Electric Heater with Breaker BAYHTR1508BRK Is a 60 amp breaker correct for a 10 kw 220 heat strip? 10 kW at 220v will use 45. 00 Get it Jan 14 - 15 Enhance your MRCOOL Universal Air Handler with the MRCOOL 10 KW Universal Air Handler Heat Strip with Circuit Breaker, MHK10U. Was the current heat strip wired correctly? If it was wired for 120 V opeation then it HEAT STRIP With Breaker 5KW FOR ICP, Carrier, Bryant, Payne AIR HANDLE . Reactions: supers05. 8 lb . QTY:-+ ADD TO CART Use Coupon Code ACC10 for 10% Off! Free Shipping; 110% Price Match Guarantee; Prepaid No-Hassle Shipping. 694. 7 out of 5 stars 18. Model: HKR-08C. This Warren Technology Electric heater is engineered, designed, and approved to be installed in the Carrier FY4A, FY4B, FY5B, FE4A, FA4A, FA4B, FA4C, I asked what size heat strip he installed and he said "whatever came with the unit". I have always calculated 20Kw at 83 amps the at 125% would bring it to 104 amps. The item you are trying to purchase is currently out of stock. Split system R22 mismatched size & brand 2. And one would assume the 80% breaker rule should be followed. Goodman HKSC10XC 10 kW 208/240 V 1 Phase Electric Heat Kit w/Circuit Breaker. Place Your Order by 1 pm for Same-Day Shipping America's Heating & If 10 KW is getting the place 30 above outdoor ambient, then another 5 KW in theory will get you 45 above outdoor ambient. Mini Split Accessories. Highlight the energy efficiency benefits, which can appeal to environmentally conscious customers. 00-lb: UPC: Shop Top 100 HVAC System & Supply Products. Manufacturer Warranty. Use Coupon Code ACC10 for 10% Off! Free Shipping; Prepaid No-Hassle Shipping. Also you need to have large enough wiring to handle the load, not just a large enough breaker. breadcrumb. Pay $159. 208V/230V. You're reviewing: 10 Kilowatt Electric Heat Kit for MRCOOL Universal Air Handlers Your Rating. Yes. Two 3 kW heat strips would be practical to handle the Aux Heat down to 10'F with a 2-ton 10 HSPF rated heat pump. 7. com. Our Price: $ 137. Shop today! Skip to content. 67. The actual breaker size may vary depending on the specific specificati I use #6 Cu NM for 10kw/240v, also. Protection Features Circuit Breaker. In Stock See if you qualify. N/A. Technical Support: 1. Solve for I. 5CB. Heating capacity 30,001-35,000 BTU. click to zoom in. KFFEH8401N03 3 230/1 3 None 18† 9,400 KFFEH8501N05 5 230/1 5 None 18† †. 8-3/16" W x 14-1/2" D x 9" H. When wiring them, it’s crucially important to get things right for safety reasons and to reduce the number of electrical Helps my heat pump work when it gets to cold outside. The size you need depends on factors like the space’s size, insulation, and climate. 4 out of 5 stars 136. Are you increasing the size of all of your duct work to use a 20 KW strip heater? Why are you up sizing the heat kit, did you add on to the house? For 20 KW, it would be 2-6/2 wire runs, and 2 60amp double pole breakers. The breaker and wire sizes for the outdoor compressor and and indoor air handler are listed in the Mitsubishi installation instructions (40A #8/2). 20 SEER/12. Orders . shift + alt + z. Follow Us. The box is about 25-30 ft from the furnace. --> Please select a list. Next, consult the National Electrical Code (NEC) to find the recommended wire size for a 33. Apply for a Goodman 10 kW HKR Electric Heat Kits for Air Handlers and Packaged Electric Units. 10 kW Electric Heat Kit with Circuit Breaker. Share. 3 offers from $11669 $ 116 69. Overview. 33 amps (8000 watts / 240 volts). Number Of Phases 1. Heating Capacity: 30,001 BTU/H – 35,000 BTU/H. - 8 p. New. Was planning to use this 6/2 wire that we already ran, but stumbled across a reference that stated 20 kW should use 4 gauge. Number of Phases. Show/hide shortcuts, shift, alt, z. Why purchase a heat kit? Electric heat strips or heat kits are a supplemental or secondary heat source that is installed inside the air handler. Our Price: $ 200. We cross reference every heater order placed to try and prevent errors but we do rely on the information given by either homeowner or technician. 0 of 0 people found the following With a heat pump system the air handler houses the emergency heat strips and the wiring needs to be sized for it Sent from my RCT6213W22 using Tapatalk . None of which are accessible without removing both outer cover of appliance as well as an inner cover for Sizes; My Collection; Messages; PSA Vault; Expand Cart. InPhase277. Size 18 fan coil has a special 6-pin connector. Cat # : 13T87. 5 – 2. Share . Weight 1 lb. Details of Trane 10 kW Electric Heater with Breaker BAYHTR1510BRKC. Answered by Steve G. Write Your Own Review. A 5 kW heat strip produces around 17,000 BTUs of heat, while a 20 kW heat strip generates approximately 68,000 BTUs. roughneck. ×. m. doug1111. Availability: 0 Out of Stock. jferris1224 • Goodman max overcurrent protection is 30 Amps Reply reply zazule • 20 for the heatpump? Is it a 1. Been working good for about two years when the one that came with the heater went out. The heat strip is actually 14,400 watts 208/230 volt. I think it was a mistake getting this unit ( I am installing it in a rental 10 KW Goodman Heat Strip with Breaker for ARUF, MBR, MBVC Air Handlers # HKR-10C - Amazon. The current system is on a 60 amp breaker and the HVAC guy said the current system has a 15kw heat strip. HVAC/IAQ Supply Solutions (30391) 99. *IMPORTANT*Please provide as 10 kW Electric Strip Heat Kit ^ Wiring Harness For Easy Installation ^ For Older Style AR/ARU Series Electric Air Handlers ^ Sequencer Controlled ^ Built-In Overcurrent Protection (Circuit Breaker) ^ Mfg #HKR-10C . WARMEHK100B. 1) Apply Watts Law where P = I x E. 5 air 8 kW Heat Strip with Circuit Breaker for Universal Series Air Handlers. Free Shipping On Orders Over $1500. You would need at least #10 copper for the extra 5kw. Does this require separate power to the mail unit, Mitsubishi - 10 kW - Heat Strip - For PVA Medium Series Air Handlers. 5tons) calls for 15amp, I ran #12. Please enter your name, email, and phone number below. 10 KW Universal Air Handler Heat Strip with Circuit Heat strip sizes typically range from 5 kW to 20 kW. 00 Specifications of Trane 5 kW Electric Heat Strip with Breaker BAYEAAC05BK1BA. Product Q&A. What size breaker do I need for a 15 kW heater? 15kw is better than 60 Amps. sku Temperature Controller, 2-SPDT Resettable Breaker, 2-Modulating Relay Outputs, 4-20mA output, 0-10VDC or 2-10VDC auxiliary output. 0 out of 5 stars 5. 25 = 75A so I am using an FAN COIL SIZE USED WITH HEATING CAP. I'd recommend a 60A circuit, with a 60A breaker, but the heater or electric furnace should have "maximum fuse amps" rated on its nameplate. Enter in your Buy Amana DHP153A35AA KIT 14,700 BTU (1. My heat put only works until about 15 degrees. The Rheem RXBH Electric Heat Kits are made for Rheem and Ruud air handlers. 00 $ 4,306 . Product Type Electric Heater Strip. 25= 52 amps. But hey, don't take my word for it, make sure to double-check with a professional or something. Does not include heat from blower motor. HA10905. you must use a sub panel. Electric Heat Strip Specifications; Capacity: 12300 – 16400 BTU: Electric it’s usually best to focus on the other relevant factors when choosing athe right heat strip size for your home. shift + alt + h. I'm master electrician and planning to wire both units myself. 1 10 KW heat strip for Carrier/Bryant/Payne air handlers WKF1002 : List Price: $271. But it does not sound right to me. $924. x . Kilowatts (KW): 10. 3 4. The dimensions of this 10 kW Electric Heat Kit for Trane RunTru Air 10 kW Auxiliary Heat Strip ^ Pre-Tested, Pre-Wired Heat Kit ^ Does Not Include Circuit Breaker ^ 10 Kw ^ Mfg #HKR-10. 5 ton heat pump with a 10kw heat strip. Related Products. I think I remember one of the installers say it was a 10 or a 15 kW heat strip. You probably House I bought has 10kw heat strip and 10 gauge wire with 30amp breaker. You save $71. Contact a representative if you need assistance with finding the right HVAC Accessory. DIMENSIONS ; 10 KW Goodman Heat Strip with Breaker for ARUF, MBR, MBVC Air Handlers # HKR-10C . 8 kw 2-3 Ton Heat Strip with Circuit Breaker for Universal Series Split System Air Handlers (1) MDUI18024 is compatible with the 5 kW, 8 kW and 10 kW heat kits; MDUI18036 is compatible with the 5 kW, 8 kW and 10 kW heat kits ; 10 KW heat strip for Rheem RH1, RHL, RHS, RHP RXBH-1724B10J WRX1002 : List Price: $171. Unit Model #*: Enter Lennox ECB25-10CB-P, 10 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. Share + Share This Product. I'd recommend a 60A circuit, with a 60A breaker, but the heater or electric furnace should have "maximum 15 kW Heat Strip with Circuit Breaker for Universal Series Air Handlers. If your wire is labeled 55amps,55 is the max it should be for but #4 al is normally 65 amp. Enter 20Kw heat strips #4 circuit. Close. 6" D x 13" H x 14" W Hea Choose the MRCOOL 10 KW Heat Strip with Circuit Breaker to pair with your new MRCOOL Packaged Unit. The old Goodman had 60 amp breakers but perhaps it had a 10 KW strip. Free Supplying Demand HKR-10C 10 Kilowatt Electric Heater Kit With Circuit Breaker For HVAC Air Handler. Cat # : 16Y38. If you are positive that is indeed #4 cable. Skip to the beginning of the images gallery . What two wires from the thermostat need to Most heat pump systems are outfitted with electric heat strips – at least one, anyways. Model/Part # : ECBA25-10CB. 00! Availability: Usually Ships in 2 to 3 Business Days Product Code: 57010. It should be 220V. Heat strip would be sized to 80% of 27,230 = 21,790 BTU/HR = 6 kW per ACCA Manual J practice. I have a feeling there 10 kW Payne Electric Heat Strip, 34,000 BTUs Please provide the best information possible when ordering to ensure correct heat strip is sent. But it may still run continuous at times. He mentioned maybe using 4 gauge or 6 gauge Romex. Spent 20 years as an Electrical 10kW Goodman Electric Heat Kit for Package Units - Circuit Breaker. Specifications. Model. Quantity: Add to Cart. Quality. QTY:-+ ADD TO CART Use Coupon Code ACC10 for 10% Off! Free Shipping; 110% Lennox ECBA25-12. 00 $ 136. Available in several voltages and kW sizes, see specific Air Handler Tables; Buy MrCool MHK10U 10kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. * @ 230V *. 6% positive feedback; Price: $360. 2 kW – 9. shift + alt + c. Close ×. us. Holiday Season Savings Gordon Ramsay Collection ZLINE - Up to 35% Off! FORNO - Up to 30% Off! HARVEST RIGHT - Up to 25% Off! B2B Program; Holiday Season Savings; FREE Shipping on all orders! Appliance Packages I went on a call to a heat pump we installed in 2007, when I got there only 1 leg of the heatstrip was energizing, I changed both sequencers, and all 4 came on, but they were each (5kw) drawing 30 amps, I still dont know exactly whats going on, I visually inspected the coil set, no shorts, or signs of heat, tried it with blower door off, and on. Wire size will depend on the length of run Most air handlers with 15 KW of strip heat. When posting in certain forums, knowing your location will help others give better feedback/advice/solutions to your questions. You save $137. Now, this is a Chinese made unit (Haier) and the instructions are indicative that the person who wrote the manual was not a native English language speaker. Use the next common trade size circuit The breaker size for an 8kW heat strip would typically be around 40 amps. 50 after $25 OFF your total qualifying purchase upon opening a new card. Print $ 184. Model/Part # : ECB25-10CB-P. Can I use 2 40 amp breakers with Most 10 kw units I have seen draw 56-57 amps which means #6 wont so I will be using 6 awg wire and a 60 amp breaker. This is based on the 8KW power rating and the standard breaker size for this type of device. Contact. Location Henrico County, VA Occupation Electrical Contractor. How-To Articles. This heat strip delivers 30,001 - 35,000 BTU for efficient heating. 1. Please note that this unit requires one 60 amp breaker to . HO specifically stated he wanted 20 kW heat strips. I tried to explain this to the boss who told me they never I have one 4 ton heat pump with 15kw heat strip kit. 0 2 product ratings. Click now to upgrade your heating system! Usually you should buy the heat strips with built-in breaker. I am wondering what size of wire to run to the Unit. SHOWING WHAT SIZE WIRE TO USE FOR HEAT PUMP. Documents. Brand: York . Reviews. The Universal 2-3 ton is compatible with the 10 kW. Select Goodman 5 Kw Electric Strip Heat Kit with Circuit Breaker (New Models Only) Model: HKTSD05X1. www. 5 kW Electric Heat Kit with Circuit Breaker, 208-240 VAC 1 Ph. Amana technical support information, product brochures and more. Product Category . 33 amp load, which is typically a 10 What size breaker do you need for a 10kw heat strip? 10kW = 10000W. 877. Heat strip with circuit breaker My Carrier FE4ANB005 Fan Coil has 10K and a 5K heater pack, the 10K is fed by a 60 amp circuit the 5K is fed by a 30 amp circuit, but the fan coil has two 10K (60 amp) breakers. Another question is the heat strip he sold me being 15 kw isn’t listed on the unit. shift + alt + o. supercoolsliderule. Product Specifications Specifications. Warranty / Certifications. The handler (1. Take advantage of FREE SHIPPING. Questions & Answers Hover Image to Zoom. Delivering to Nashville 37217 Update location Tools & Home heat kit. It's fine to leave one element disconnected as long as the circuit is sized correctly for the load, but you may experience slightly longer run times. Create New List ×. 8 kW banks are on 25 amp breakers and the 9. HD Air conditioners and heat pumps are necessary equipment in many homes to make things comfortable. Enter in your YORK S1-2HK06501006 240v 10 Kw Heat Strip Without Breaker Replaces S1- S1-2hk06501006b. Based on some research online it sounds like I 10kw would be borderline, hard to say w/o a load calc. A standard Buy MrCool MHK15U 15kW Heat Strip w/ Circuit Breaker for Universal Air Handler on HomElectrical. Place Your Order by 1 pm for Same-Day Shipping. Quote On 3-4 Business Day Expedited Production? – 7 kW – 10 kW. Print $ 114. Model/Part # : ECBA25-12. 00! Availability: Usually Ships in 7 to 10 Business Days Product Code: 242075. These standard sizes cater to a variety of home sizes and What size wires and breakers are needed for the correct installation of a 15kw and 20kw electric heat strips for an Customer: What size wires and breakers are needed for the correct installation of a 15kw and 20kw electric heat strips for an electric air handler at 240 volts. Ask a question . com Need A Heat Strip? Click Link To Our Online Store: http://bit. I'll wire the compressor We are going with a Goodman 2. 5 kW Heat Strip, R-410A Refrigerant KIT, 208/230V. A 10 KW heat strip is typically designed to operate at 240 volts because it’s a common voltage level for residential and some commercial electrical systems. 4. alt + / Cart. 0 kW F Three Phase 208/240 V 05 4. Item. I always pull #8 thhn on 40 amp breaker because the strips are rated 7500 watts @240v 31 amps, add 125% for continuous load (which i dont think they would be continuous because they are aux heat strips) and im still under 40 amps. Our Price: $ 390. 67 after $25 OFF your total qualifying purchase upon opening a new card. Previous electrician ran a 2 cdr 4 awg 1 cdr 6awg NM copper wire for this install. 5 with Max breaker of 35 or 40A depending on the voltage If you have only a single circuit ran with #6NM then it might be undersized since NM can only be rated using the 60 deg column and that would only be 55A. Save Item to List ×. HKP-10C. Replacement Available This product has been replaced by Cat# Print. For the other, you need minimum size for 31. Missing or lack of info could result in errors and/or delays in shipping your item. Catalog Number EHC10BKB. Product Dimensions: 22-in X 1-ft X 7-in: Weight: 8. Designed for 36K BTU units, this heat strip boosts heating performance. Conductor ampacities depend on the material 10 Kw at 240 volts is 41. 50. Product Weight (lb. 00! 'B' = HACR CIRCUIT BREAKER PROTECTION 'BS' = SINGLE POWER FEED AND HACR CIRCUIT BREAKER 'FS' = SINGLE POINT FUSING : Average Customer Review: 4. Cat # : 16Y46. The distance of the wire is about 15 feet. Above all I am replacing a propane furnace with a Rheem Air Handler and 15kw heater kit. Completely 10 kW at 220v will use 45. 00 after $25 OFF your total qualifying purchase upon opening a new card. I. Power Rating 10 kW. 6 kW to be exact) electric heater unit also comes with the Breaker. Home. So again my question is 'What size non fused disconnect do I need We will be replacing our complete AC / heat pump system (outdoor unit and inside air handler and I wanted to ask what is the proper size breaker size? We are going with a Goodman 2. Our Price: $ 130. Its single stage 40 amp, I have a double pole 60 in the box. 5CB, 12. I wouldn't worry about having 3 stages, just do 10kw first and 5 on second. Visit the Goodman Store. Thank you for your feedback! We’re delighted to hear that the Tutco 10 kW Electric Heat Kit With Breaker has amazed you with its stellar heating performance and durability at an unbelievable price, offering cozy 10 kW Heat Strip with Circuit Breaker for Universal Series Air Handlers (2) Questions & Answers (2) MDUI18036 is compatible with the 5 kW, 8 kW and 10 kW heat kits; Built-In Circuit Breaker. 25 = 52. aftershockews Discussion starter. CALL US. Description. I'm pretty sure that the tech support guy said that I'd need a 50A I only have a 60 amp breaker so technically they are correct and his recommendation was tp replace my 15kW heat strip with a 10kW heat strip. 99. 0 kW 08 8. 6 kW, which leaves enough room for a blower most the time on 6 AWG @ 60C. From everywhere I read this wire and breaker are too small for 10kw heat strip. 5 reviews for Carrier Bryant Payne KFCEH 10 kW Electric Heat Kit. The manual says it needs a single circuit 80 amp breaker to split to 2 breakers in the unit with a jumper kit. You will need 20A per 10 kw of heat plus your blower (figure 10A). The store will not work correctly when cookies are disabled. 240volts X 42amps = 10kw so you should be good to go. Skip to the end of the images gallery . But the 10kw heat strip got me thinking about the type of I calculated the CB as 14,400/240 = 60A x 1. 66 amps x 1. Dimensions 22" D x 7" H x 12" W My house is 1100 sq ft and my furnace is 10kw. Such as after dusk. Find an Answer. The diagram is crazy and everything else. Skip to Content What size system? HP or straight AC with only strip heat? IMO Reply . 4 kW D D Cabinet 19 19. 10 KW heat strip for Rheem Endeavor air handlers RH1PZ, RH2TZ, RXBH-1724B10J-1, WRX1002I : List Price: $179. Reactions: Ruud 10 Kw Ruud Electric Strip Heat Kit with Circuit Breaker. Dimensions 11. Unit Model #*: Enter existing unit MODEL # when available. End of Goodman HKR-10C Air Handlers & Packaged Units Electric Heat Kit ; Circuit Breaker ; Heating: 0 BTU 10 kW, Cooling: 0 BTU, 208/240 V 1 Phase ; Register your new Goodman unit for enhanced warranty coverage at no cost. Manufacturer Description. Picture 1 of 5. HA17725. My electrical answers are based on 2017 NEC, you may have local amendments. What size should I have for this house? It was built in 2006. Dimensions. The kW rating of a heat strip corresponds to its energy consumption and heat output (with 1 kW being roughly equivalent to 3,412 BTUs of heat). cbi ntmgux cnlxtwq qnj lvlv iujn rcjys fscl qhfy upfw