Digitrax ds64 Digitrax DB150 Command Station/Booster Power On LED Diagnostic BlinkingSteady on = DB150 is operating as a Command Station/Booster 1/2 sec on / 1/2 sec off = DB150 is operating as a Booster only 1 sec on / 1 sec off = DB150 is in Option (OP) mode, the Option switch is in the OPTN position 2 sec on / 2 sec off = DB150 is in Sleep mode, the Option Oct 11, 2016 · Looking for a straight answer on DS64 power sourse options along with Loconet. I am having issues with a Digitrax DS64. Easily hook up external DC power either by a PS-14 connector or to a terminal strip. Stationary Decoder for use with 4 slow motion, solenoid, or bi-polar turnout machines. Local turnout control. Here are the questions. Using track power can induce problems as power drops can occur the farther you move from feeders. Control panels stick out into aisles and therefore need to be rugged. : 1) There appears to be 5 ADDRESSES programmable in the DS64. Unpack the DS64 and mount it in a location with easy access to the turnouts you want to control. 7 4. 7 out of 5 stars 25 ratings | Search this page . Digitrax sells PS14 power supplies for this purpose that are rated at 14 volts at 300ma. com. Only one type of turnout motor can be used on any particular DS64. On some rare occasions they don't The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. It is connected in this way: Apr 15, 2011 · The DS64 has a latching type of operation in that a pulse of voltage (the switch being depressed) causes the DS64 to toggle (flip) between two states. Even Kato's SwitchKat does not do that. After that, it got so hot it melted the platic over the ventillation grill and all four of the outputs showed about 4 Nov 23, 2015 · This is also documented in the file section of the Digitrax group Randy referred to. The PL10 has four wires to be attached. I seem to be having problems operating atlas switches via a Digitrax DS64. This caused the DS64 to operate the Tortises as double solenoid type machines, which is the default, and which apparently will blow out all the outputs on the DS64 as soon as it powers up with Tortises connected. May 24, 2011 · To set up your DS64 to operate stall motor type turnouts: 1. If a mistake is made on one, it won't effect the others. I have no personal experience with it, but if it is DCC-compliant (not reason to think otherwise), it should work equally well on any DCC-compliant DCC system. Allan Gartner photo. Jan 10, 2012 · The DS64 is a powerful stationary decoder. Connect the DS64’s ‘TRKA’ and ‘TRKB’ terminals to your track. 1 above. The back edge has two LocoNet connectors and a barrel style power supply connector. Feb 5, 2020 · Can the DS64 be connected to the rails to receive a DCC signal from any controller? I am planning to get the Digitrax DCS210 Advanced Command Station and use LocoNet once I have track down on a larger more permanent layout. depending on the switch motors u use slow motion or snap i. Learn more on our website at digitrax. Aug 7, 2014 · How do I connect a BD4 to a DS64? The BD4 is a block occupancy detection device designed as an add-on device that can take advantage of the LocoNet hosting capability of the DS64 stationary decoder. Logged w neal. So easy. e. Apr 20, 2020 · Digitrax recommended a DS64 to take the sensor inputs. I am about 99% sure I have a faulty DS64 but any advice you can give me is appreciated. Features: Quad switch decoder for Solenoid or Slow-motion turnouts. Leave this field empty if you're human: Payment Options. I enter "1" for thrown. the clank is a by-product of using those coils. Only one DS64 can be powered per PS14. May 24, 2011 · Note: The DS64 is configured for either for solenoid turnouts (the default setting) OR slow motion turnouts. Feb 22, 2009 · Digitrax DS64. | Print Article | Leave Feedback KB805 DS64 - Setting Board ID for Additional DS64s. KB805 DS64 - Setting Board ID for Additional DS64s. The literature says that you can only use May 24, 2011 · At the factory, your DS64 was set to control solenoid type turnout machines that use a single pulse output for operation. A1 will trigger route1, S1 will trigger route 2, and so forth. Feedback of turnout position, including "out of position" during changes. Jan 16, 2012 · The momentary push buttons are connected to the DS64 inputs marked S1, S2, S3 and S4. To program the DS64 Route Number, use your DCC throttle in Switch mode to select a Switch Address from 1 through 8 and issue a Closed or Thrown command. When used in conjunction with the DS64 or SE8C the BD4 provides LocoNet detection for 4 occupancy detection sections. Dec 15, 2010 · "Multiple turnout machines can be operated on a single DS64 output. Signaling system control messages The BD1 is also compatible, for the same purpose, with the DS64 and SE8c. This can be done with DS64 and BD4. 75" (length) x 3. I plan to use routes with some stored in the command station (DCS200) with others as local routes stored in the DS64 where some local routes may involved turnouts Jan 16, 2012 · We have determined that the Fulgurex motor draws too much current for the DS64. KB673 DS64 Stationary Decoder-Power & RailSync. DS64 #3 and 4 are used only for turnout setting. However, I see now that Digitrax has replaced them with DS-74s. Sep 22, 2023 · If you have tried resetting the DS64 by closing Option Switch 7 and that has not worked for you, please try resetting the Digitrax system (DCS50/51, DB150 or DCS100/200) by closing Option Switch 39. Make sure the momentary-on push buttons are wired as shown in Fig. Aug 19, 2024 · That is a stationary decoder. It seems to me that there should not be a problem, but one fellow told me not to do this. KB520 General DCC Power Supply Information. Can support on expansion header up to 4 DSXCP1 fascia SW control panels with SW direction indicator LEDs. Mar 31, 2023 · Jeff, my research on the DS-64 indicates an extremely versatile decoder. You are now ready to set up a Route. Nov 18, 2019 · Unfortunately Decoder Pro does not yet have any provision to program routes on a DS64. The DS64 requires 300mA for proper operation. DS 64 Power. And on the Digitrax site it appears that half the people had issues the could not be resolved but the other half did not. Find out more about the DS74 on digitrax. Leave the jumper block on both pins of JMP1 on the MRD8. The LocoNet cable is used only for LocoNet commands. The use of Third-Party Software LocoNet Checker allows for quick and easy programming of Routes in your DS64. How to use Slow Motion Turnouts on the DS74 - Learn how to use Slow Motion Turnouts on the new DS74. QUICK LINKS. How to use Lamp Mode on the DS74 - Learn how to use Lamp Mode on the new DS74. Works with compatible LocoNet Systems. According to Digitrax tech note KB273, this configuration cannot be used as the Fulgurex takes “about 400 mA” when running, which exceeds the specifications of the Digitrax DS64 as well as ones of the NCE Switch-8. 00. Turnouts can be either connected or not. They are horrible. Differences in the DS74 from the DS64: Up to date and compact LocoNet design with customer IPL/firmware field update capability using DigiIPLII. Tortoise or other slow motion swith machines can be wired in two different ways. Jan 20, 2012 · I am trying to wire my new layout (N gauge) using the DS 64 with Peco switch machine PL10. Apr 17, 2021 · Check the Power supply. The PS14 power supply can be used with Auxiliary or the rear modular power connector. Digitrax PM4, BDL168, SE8c and DS64 boards use a special messaging protocol to program their Op Switches. Digitrax DS64 Quad Switch Stationary Decoder. Mar 23, 2017 · I am using DigiTrax DS64's to address the Kato turnouts. I currently have a Digitrax DS52 controlling two turnouts with Tortoises, but I have more I need to control, and I also want to get out of using track power as I’m planning to use more locos with sound. The DS64 works with a wide selection of hardware. Find Support by Product. Peco u will have to change it through the ds64 , the ds64 will operate either ,if u have any problems call digitrax they are great with customer service The Digitrax manual has next to no info on how to wire the inputs for the DS64 stationary decoder. Digitrax Owners Manual: DS64 Accessory Decoder If you have any questions or feedback regarding this advice, please feel free to contact us at salesuk@dccconcepts. | Print Article | Leave Feedback Feb 3, 2013 · Digitrax DS 64 Jump to Latest 2. " so this i'm happy about thanks on input clarification. To open this tool select "Configure DS64" from the LocoNet menu for the connection this DS64 is attached to. 13, 2011, 6:43 p. The routes are programmed one at a time using the button on the DS64 and a throttle. KB594 Is Digitrax signaling and detection equipment compatable with other DCC systems? Q: I have a Lenz Set 100 and was wondering if I can use my DCC system and use the Digitrax signaling and detection components. I am VERY unhappy about the way that the solenoids work on all of my Bachmann turnouts. Up to 4 Kato Unitrack switches (such as the Unitrack double crossover) can be operated a on a single DS64 output. I find conflicting info in the Digitrax tech notes for the DS64 concerning use of Loconet with the various optins for applying power to the DS64. May 24, 2011 · OpSw 08 startup delay and power management of DS64 OpSw 08 doubles the DS64’s startup delay. Dec 20, 2017 · My question arises from having 4 turnouts in my layout plan, and other than purchasing a Digitrax DS64 or 2 DS52's, I don't see any other way. ? Slow Motion Machines. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder KB812: DS64 - Diagram This article was last updated on May 24, 2011, 6:41 p. Jun 29, 2022 · I have several DS-64s I am in the process of installing on my layout and I was going to purchase some more. Configurable for on/off control of 8 layout lights. We will generate one route for each track. Mar 28, 2017 · Afterwards it wants a cv value. 0 bids · Time left 5d 3h +$15. Q: Is it possible to use Digitrax equipment to wire the Kato N-Scale Automatic Track Crossing? If so, how do I do it? A: The answer is a probable "No", but there may be a workaround. my question is is there a way to add led lights to so i can just look at the panel to check the direction of the switch. You will need to set the DS64's board ID if you are planning to use the DS64's 8 inputs with a computer, system throttle, or other smart device on your layout that needs to know when a turnout has been May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder KB802: DS64 - Route Table This article was last updated on May 24, 2011, 7:21 p. 11 £ | Model railway digitrax: 37. Currently unavailable. It is about 1/3 the size of its predecessor, the DS64. There are three different ways to power the DS64. m. Fulgurex and NCE Switch-8: Does not work together Feb 26, 2011 · I'm using digitrax DS64 stationary decoders to drive Peco coil/solenoid switch machines (installed underneath the track). In this case the two states are the direction of the DC voltage being sent to the tortoise. 95 delivery. All plug-in connections. Jan 25, 2016 · DS64. I know this is probably way more trouble than what it's worth. Configure Digitrax DS64 The JMRI DS64 Configuration tool lets you configure the internal options of a Digitrax DS64 Stationary Decoder directly from your computer running JMRI. I read where the DS64 is a nightmare in that it throws the switches upon powering up not sure about the DS52? Digitrax devices which make use of "Board ID" numbers, but which cannot be programatically configured, include: Digitrax DS64; Digitrax BDL16, BDL162, and BDL168; Digitrax PM4, PM42; Digitrax SE8C; Digitrax BXPA1; Digitrax BXP88; For these devices, JMRI cannot configure the Board ID number under JMRI's control without user intervention. Important Note: You cannot cascade routes within the same DS64 route table. Digitrax-DS64-Manual-2014. No turnouts should be connected to the DS64 at this time. I joined both the Digitrax and the MRC yahoo groups and read through everything that had to do with DS64 decoders. Find instruction sheets, specifications, case studies, and 69 articles on topics such as powering, programming, and connecting turnout machines. Turns out the problem was that I connected and powered up the DS64 to the Tortise turnouts BEFORE I set SW01="c" for stall type turnouts. Block occupancy detectors, using Digitrax BD1 detector modules. Note: If you find that your turnout is operating “backwards” simply switch the + & - wire connections to achieve correct operation. Normally, I would just go with the upgraded product, but I am reading conflicting information about the new auxiliary stationary decoder. Jul 21, 2021 · Differences in the DS74 from the DS64: Up to date and compact LocoNet design with customer IPL/firmware field update capability using DigiIPLII. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder KB808: DS64 - Choose either solenoid or slow motion turnouts for a single DS64 This article was last updated on May 24, 2011, 7:07 p. ” If you have reconfigured your DS64 for stall motor type turnouts, the DS64 can be reconfigured back to solenoid type turnout motors. Some additional information for the DS64. You ideally want 1 power supply for each DS64. We made good use of the Digitrax DS64 staion Dec 13, 2021 · DS64 - all outputs must be the same type of motor (selenoid or Slo–mo) 4: DS54 - an external switch must be wired for turnout position reporting to computer. The DS64 "latches" in either position so the push button fascia switch does not need to remain depressed. To reset DCS52, DCS210 or DCS240 close Option Switch 40. as i understand it you can also add switches so it can use both the dcc signal and the push button. Please refer to the DS64 manual and other Tech Support Depot articles for additional information on programming Routes. I thought by wi Digitrax available from Coastal DCC. Stationary Decoders -> Quad Stationary Decoder (DS64) The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. JMRI supports this mode in Roster-based programming, so you can treat these types of boards in much the same way as you treat mobile decoders in your locomotives - you may program them using the JMRI "Symbolic" programmers (i. There are many transformers and power packs that can supply input power for Digitrax boosters & command stations. He thought that there might be a conflict between the outputs of the Kato control switches and the DS64. When using more than one DS64 in a DCC environment, you must assign a Board ID to each additional DS64 so that each one has a unique Board ID. DS64 Quad Stationary Decoder. They do not keep the points tight against the rails Jun 15, 2009 · The PS14 is a 300ma, 14 Volt power supply for powering Digitrax accessories like the UP5, BDL168, DS64, SE8C, LNRP, UR90, UR91 UR92 and others Universal AC input 95-240V 50/60Hz US 2 prong plug, in sideways orientation Jul 3, 2018 · I use the ds64 with tortoise switch motors and the NCE PC it works great. 72 £ Jan 25, 2016 · Can a DS64 be powered from the LocoNet RailSync lines? No. I started out with (8) Digitrax DS64 quad decoders, which are well documented to work with my equipment. May 24, 2011 · Note: If your route includes switch addresses from more than one DS64, they must both be connected to LocoNet or the route will not run. It all works great using a DT400 throttle, but I can't figure out how to make it work using the local inputs. Model Railroader. This allows for adequate current for the switches. From Solenoid turnout machines to slow motion motors, this affordable, easy to install decoder will add another dimension to your operations. Aug 8, 2014 · Is this possible using the DS64 inputs or the Tortoise connections? The DS64 does not have separate connections for indicator lights for trackside or for a control panel. Sponsored. The DS64 board ID is "1" so I set the sensors up in the sensor table as LS1, LS3, and LS5. 1. Local route control. On the DS64 press and hold the OPS button down for about 3 seconds until the red OPS LED and green ID LED begin to blink alternately. the Roster). May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder; KB813: DS64 - Connecting to LocoNet. | Print Article | Leave Feedback This example is a small yard with a crossing signal at its entrance. What about other DCC systems?A: Yes, Digitrax detection and signaling will work with any DCC system. However, I am not getting rid of all the track I already purchased. Is there a way to stop all the DS64 switch decoders from throwing switches once the power is switched on? Almost every time I turn the layout on the switches throw opposite. My question is: Do I need to attach all four wires or just one set of wires? The PL-10 is a coil-type switch machine with double solenoids. I want to power them from an external power supply, not from the track. Opens in a new window or tab. Press and hold down the STAT button on your DS64 until the green LED begins to blink quickly. Handles Kato Crossover switching with no issues. Sep 13, 2011 · Using the gate in a DCC environment will require the operation of the gate mechanism, and it will require train detection so that the gates work when a train is approaching. Why when all it supports are 4 turnouts? 2) According to the Digitrax video as one adds more turnouts the led flashes faster each time. Plug and play wire connectorization. For larger routes, you can set up Cascading Routes by using multiple DS64s. | Print Article | Leave Feedback Digitrax DS74 Quad Switch Stationary Decoder Replaces DS64 All Scales. Subscribe To The Digitrax YouTube page! Join The Digitrax User Group. I know Digitrax has the DS64 which controls four machines, can use its own power supply and Aug 19, 2024 · That is a stationary decoder. 12 £ | Gauge model railway: 516. If you are using solenoid type turnouts, you can install the DS64 “out of the box. The return connection of each push button is made to "+COM. Each output capable of handling 4 Kato turnouts. Find many great new & used options and get the best deals for Digitrax DS64 Stationary Decoder For Use W/ 4 Slow Motion T/O Machines at the best online prices at eBay! Free shipping for many products! Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder Digitrax Products -> Detection and Signaling -> BD4-Quad Block Detector KB391: DS64 - Sensor Activated RR Crossing Lights with the addition of a BD4 May 24, 2011 · The DS64 has a route table that can hold up to 8 individual routes that consist of a "Top" address and 7 additional turnout addresses and their positions. Dec 16, 2018 · I am setting up 4 Digitrax DS64 on my layout to run a bunch of Tortoise switch machines. 5cm (height) 4. If you are using LocoNet, connect one end of an RJ12 cable to either of the DS64’s LocoNet sockets and connect the other end of the cable to your existing LocoNet network. Pre-Owned. Switch commands will be sent through the rails to the DS64. Note: The wires that connect the BD1 to the rails and rail power source are characterized as two heavy, uninsulated, and polarity neutral wires. This indicates How to program the Digitrax DS64 for slow motion switch machines such as the Tortoise machines on your DCC layout. (3) DS64s were purchased new from Dallas Model Works in 2022 before their supply ran out. I want to use several DS64’s to control turn outs (PECO). cctuna February 22, 2009, 1:14am 1. Brand: Digitrax. | Print Article | Leave Feedback Jan 25, 2016 · The power supply used must provide enough current if it is powering more than one DS64. The route programming is done with the DS64 connected to an active Digitrax command station by a Loconet cable. Jan 19, 2012 · Specifically, can DS64 defined routes include turnout addresses controlled by other stationary decoders connected to the track bus but not connected via LocoNet? LocoNet is the conduit for information outside of a specific DS64, including external devices controlled by a particular DS64. i would preffer to not have the clank but since i decided against stall motor machines i have to have it. The board addresses are set to 1 to 4 while the switch addresses are programmed in sequence from 1 to 16. The DS54 has been discontinued by Digitrax. I'm not sure whether it's a DS64 issue or a Loconet issueBut here goes: I'm running a Radio Super Cheif system with 9 UP5s, 1 UP91, 9 DS64s, 1 UT400, 1 UT400R and 1 UT4R. Use PS14 (external power supply) to power the DS64 not track power. Jan 10, 2012 We have 1 Digitrax DS64 manual available for free PDF download: Manual Digitrax DS64 Manual (21 pages) Stationary Decoder for use with 4 slow motion, solenoid, or bi-polar turnout machines DS64: Figure 3 shows one Azatax MRD8 octal infrared train detector connected to the eight inputs of a Digitrax™ DS64 stationary decoder. Jan 13, 2012 · Why does the DS64 generate multiple output pulses for a single command? I get between 2 and 5 pulses over a period of about 2 seconds. Jul 2, 2016 · Unfortunately Decoder Pro does not yet have any provision to program routes on a DS64. This lets the DS64 know which of the 8 available routes KB386 DS64 - Kato Unitrack N-Scale Automatic Crossing Gate & Three Color Signals. When the DS64 tries to operate Fulgurex motor, the excess current draw appears to be a short circuit and the DS64 shuts down to protect itself. The following diagrams indicated how to connect the BD1 to the rails, rail power source, and the Digitrax DS54, DS64 and SE8c. Welcome to the Digitrax Tech Support Depot! Find Support by Category. The startup delay tells the DS64 to wait for a certain amount of time after the layout is powered up before ‘waking up’. Cascaded route & turnout control. View and Download Digitrax DS64 manual online. Digitrax DS64 DCC Stationary Decoder, 4 Turnouts . In the DS64 picture – it shows 2 Digitrax DS64’s, which control the switch/point turnouts. please try resetting the Digitrax system (DCS50/51, DB150 or DCS100/200) by closing Option Switch 39. The numbers 50 & 51 on the labels refer to their board ID address, and the numbers 101-104 & 105-108 is the address of each point/switch on the track, and as I am only using 3 points and a double slip, I am only using address 101 to 105. However, indicator lights can still wired to work with the DS64. The DS64 works best with the DC powers from Digitrax. Can run 4 turnouts from The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. Mar 6, 2018 · I’m looking for a DCC stationary decoder to control several turnouts (using Tortoise machines). 4. Digitrax DS74 Mar 12, 2024 · Summary: The DS64 Stationary Decoder allows operation of turnouts directly through any DCC system that has turnout control. Coastal DCC Ltd Registered Offices: Ipswich Model Railway Centre, 48-52 Tomline Road, Ipswich, IP3 8DB Digitrax for sale Digitrax sdck signal: 11. Digitrax Big Book of DCC; Decoder Selector Support Tech Support Depot; Help Desk; Video Tutorials; Manuals & Instruction Sheets; Warranty & Repair; Throttle Conversions; CV Information and Tools; LocoNet: The Digitrax Difference; Frequently Asked Questions (FAQ) Downloads Downloads; Manuals & Instruction Sheets; Sound Depot Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder This article was last updated on Sept. For example, you can run 2 Peco or Atlas Snap Switches on a single DS64 output. Over this past weekend I had a new Digitrax DS64 that apparently decided to become a plastic paperweight. Nov 24, 2021 · The new Digitrax DS74 can control up to four turnouts or eight LEDs. I’ve wired a number of control panels for clubs. Published sources describe the Fulgurex motor as needing 400 Ma for operation, which is well beyond the capacity of the DS64. Your DS64 experience might be related to that issue. Note: Multiple turnout machines can be operated on a single DS64 output. My problem is that the DS64 does not seem to be generating any messages for the sensors. ? Operates four turnouts. How to use Digitrax DS64 and BDN4 for automatic switching of turnouts. Most regular DC train control packs do not have enough power to supply the full power potential of the a 5 or 8 amp booster, since they were designed to only run 1 locomotive in a blocked system. The BD1 is also compatible, for the same purpose, with the DS64 and SE8c. Thrown (factory default) the DS64’s startup delay is 65 milliseconds times the Switch Address programmed for Output 1. Electronics and DCC. $50. The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. As the train approaches the gates, the BD4 will send a message to the DS64, which will operate the solenoid mechanism. May 24, 2011 · Digitrax Products -> Stationary Decoders -> DS64 Quad Stationary Decoder This article was last updated on May 24, 2011, 7:30 p. I am hoping some of you with experience using both DS-64s and DS-74s can answer my May 26, 2016 · Hello i just hooked two Digitrax DS 64's to my NCE Power Cab also jmri and they work perfectly. My troubleshooting found there was constant voltage on the Jun 28, 2015 · Digitrax technical support responded telling me that this is normal if the DS64 is powered at the same time that the DSC51 is powered. You can also connect switches and occupancy detectors. Can a DS64 be powered from the LocoNet RailSync lines? No. The DS64 works with a wide selection of hardware, such as solenoids to slow motion motors. Sep 22, 2014 · Hi Everyone - Please take a look at this YouTube video I made. It seems that folks with the MRC throttle all had troubles similar to mine. com or via the enquiries form on our Contact Us page. Also, we show how to wire the input and o May 26, 2007 · Thanks for the suggestions. Begin with your DS64 powered up. Mar 6, 2020 · Connecting a Digitrax DS64 to control both a Tortoise and a Fulgurex via DCC:. 2. Register for Newsletters! Register. This happens at most startups but sometimes only one DS64 throws while my other one stays. Without any changes being made to the system and without any warning the #3 output refused to respond to commands when attempting to activate the switch attached to it. or The Loconet cables could be causing problems. This affordable, easy to install decoder will add another dimension to your operations. OPSw 11 enables the local inputs to trigger the routes stored in the DS64. If using Trk A and Trk B to power the DS64, no LocoNet connection is necessary. Zephyr DCS51 to DS64 via loconet, Kato Switch factory wires to 1R/1G ports of the DS64. 8 internal LocoNet integrated System routes, that can be conveniently Can a DS64 be powered from the LocoNet RailSync lines? No. 4" (height) The front edge of the DS64 needs clearance for wires to be attached. Here, a momentary button is connected to operate Turnout 1 with a connection between S1 and +COM May 10, 2016 · NOTE: During this procedure the DS64 must be connected to an active LocoNet with an active command station. To reset DCS52 Oct 29, 2014 · 1. My plan was to just parallel the wires of the Kato control switches and connect them to the DS64. oh well. I am willing to try anything to get this to work before I send it back. DS64 media converter pdf manual download. In my case, I have one supply for my PM42, another for my DS64’s, and a third for my UP5’s. From solenoid turnout machines to slow motion motors, the DS64 hasn’t met a turnout it doesn’t like. DS64 - OPSW 21 set to closed automatically reports turnout position. 8cm (width) x 3. Apr 23, 2013 · The DS64's approximate size: 12cm (length) x 8. On the DS64’s control panel, press and hold the ID button down for 3 seconds until the green LED slowly blinks on and off. General LocoNet system input sensors. This indicates that the DS64 is ready to accept address programming for the Outputs. | Print Article | Leave Feedback When you program the DS64, you must program all four outputs, even if they are not connected to anything. I also have a programming track with the latest JMRI software and USB Loconet Interface. Digitrax Stationary Decoders Specification Sheet DS64 Quad Stationary Decoder Turnout Machine Type Control 4 Slow motion turnout machines OR Control 4 solenoid type turnout machines Switch Interface Screw terminals Turnout Addresses 4 Control of second turnout per output Yes , (Up to 4 if switches are Kato Unitrack) Unpack the DS64 and mount it in a location with easy access to the turnouts you want to control. It is recommended to power each DS64 individually. Apr 12, 2012 · Additionally, DS64 Stationary Decoders are designed to allow up to 8 Routes to be programmed internally into them. For example two DS64s will require 600mA. Mar 6, 2020 · Connecting a Digitrax DS64 to control both a Tortoise and a Fulgurex via DCC: According to Digitrax tech note KB273, this configuration cannot be used as the Fulgurex takes “about 400 mA” when running, which exceeds the specifications of the Digitrax DS64 as well as ones of the NCE Switch-8. Configurable for Capacitive Discharge with balky solenoids. Sensors can also be used with the DS64 to activate routes . 2. For Digitrax accessories, the recommendation is to power each type of device with it’s own supply. ? I have a large layout that is powered by Digitrax system and am attempting to set up 2 DS64's to control turnouts and set up routes through the yard. . For example, you can run 2 Tortoise or Switchmaster machines on a single DS64 output. In this episode of It's My Railroad we take a look at how we automated two turnouts on the Brown Smith Railroad. Track power (Trk A and Trk B), Auxiliary power (AX1(-) and AX2(+)) and power through the rear modular power connector. DS64 is set up by setting Option Switches (OpSw)This is how to set option switches on the DS64:1. Rick Allen’s Railroad with Berrett Hill Touch Toggles, Digitrax DS64 and Train Buddy custom designed electronics for massive staging Ok, so I don’t expect every railroad to use this technique to run their staging yard, this railroad is SO big and expects to have SO many locos on the track at the same time that it makes sense to power down Jul 6, 2010 · I am using Tortoise switches that are controlled with DS64s. I installed a switch in the track circuit output of the DSC51 and switched it on after the controller powered up. I am also going to email Digitrax support to see if they have any suggestions. I successfully wired three DS64's together with Cascading Routes and such. DS64 Features: ?Easy to install and operate. Option Switch 01 determines the type of turnouts that you can operate, static or pulse. 4 outputs for turnouts. This I do for all the 3 remaining turnouts controlled by the DS64. Apr 3, 2014 · Set DS64 OptionSwitches 11 and 15 to 'c' closed to enable route commands from local inputs. System Power On/Off & Run/Stop inputs. Connect the DS64 +COM terminal to the C14 or C58 terminal of the MRD8 detector. I have the buttons wired to A1 and A2 on the DS64, with the photo electric sensor wired to A3. i contacted digitrax and they KB503 DB150 Power On LED Diagnostic Indications. The DS64 must be powered via the rear modular connector (12-14 volts AC or DC) OR via the AUX power 12-16 volts DC using AX1(-) and AX2(+) on the circuit board at the front of the unit. See Article on Cascading Routes. It is also possible for the DS64 to get it's The DS64 Stationary Decoder allows you to install and operate your turnouts directly through any DCC system that has turnout control. My question is KB673 DS64 Stationary Decoder-Power & RailSync. Learn how to use and troubleshoot the DS64, a device that allows you to control turnouts directly through DCC. Mar 19, 2012 · Hi OnTheRightTrack, The DS64 has two loconet sockets in the back, so you just plug in the loconet cable into one then another cable from that one to the next DS64 and so on, then you have to set the id of each DS64, Address, etc plus the output switch numbers etc. Thanks! Jan 27, 2023 · I have spent the last week trying to successfully wire and program my control for 16 Kato turnouts. 5" (width) x 1. BD4 lets you know which detection sections of your layout are occupied by locos and rolling stock. Crew; Posts: 1434; Respect: +483; Re: NCE - throwing Kato unitrack switches Jul 20, 2021 · Digitrax Stationary Decoders Specification Sheet DS74 Quad Stationary Decoder Turnout Machine Type Control 4 Slow motion turnout machines OR Control 4 solenoid type turnout machines OR Control 8 Lamps Switch Interface Pull Out Screw terminals Turnout Addresses 4 Control of second turnout per output Yes, (Up to 4 if switches are Kato Unitrack) May 24, 2011 · Note: Multiple turnout machines of the same type can be operated on a single DS64 output. 7K views 10 replies 4 participants last post by yak-54 Mar 17, 2013 Oct 8, 2020 · A quick demo for how to use a Digitrax DS64 Quad Stationary Decoders to control turnouts on the Mon-Yough Valley mainline at McKeesport Model Railroad Club The sensor inputs of the first DS64 and the first sensor input of the second DS64 are used for the route push-buttons for panel route control. Are any of you successfully using DS64 stationary decoders to control Tortises? I purchased my first DS64, hooked it up and it threw the first turnout a few times. Feb 26, 2011 · I'm using digitrax DS64 stationary decoders to drive Peco coil/solenoid switch machines (installed underneath the track). Feb 19, 2017 · The Digitrax DS64 can be configured to operate the Kato turnouts. The back edge and left end have cooling slots which must remain clear. Aug 26, 2012 · Anyone using the NCE Switch-Kat or the Digitrax DS-64 with Kato switches? I figured out how to use Digitrax DS64 to throw points on the Kato #6 Switches. neboa fnygj uifin utcmgx xrbo dee clrjcb wugnc gwaik cphcw